<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-27 00-36-25
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 66 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.3 kHz 56 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 63 kHz 18509 3,2687
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,3 dBr 4,81 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 0:36, 27.07.2024
RT
"Rony Rex "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 63 kHz MIN: 11 kHz % above 76 kHz: 3,2687 Acquired: 2024/07/27 0.35.21 Total samples: 18509 Equivalent time: 0:15:25 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,9 dBr MIN: 3,3 dBr AVE: 4,81 dBr % above 12,2 dBr: 0,0 Last value: 4,9 dBr (2024/07/27 0.35.20) 00.22 00.24 00.26 00.28 00.30 00.32 00.34 0 2 4 6 Pm [dBr]